Variable Extraction Model Routing Failures
major- Started
- Oct 5, 3:47 PM EDT
- Resolved
- Oct 5, 2:00 PM EDT
- Duration
- —
Bland AI's updates (1)
- resolved · Oct 5, 2:00 PM EDT
At 11:15 AM PDT a provider side routing update caused variable extraction requests for fail for some customers. Some post call features were also affected including summary generations and analysis schemas. Fully recovered at 12:11 PM. Timeline: 11:15 AM - Requests begin erroring as the change starts rollout in provider's cluster. 11:20 AM - Rollout completes, error rates for affected models reaches 100%. 11:35 AM - Automated alarms page on call engineering, issue is raised to provider immediately. 11:45 AM - Bland engineering identifies issue as a routing change that expects a new model base URL. 11:50 AM - An override to the new base URL is applied, update begins rolling out to Bland clusters. 12:11 PM - All rollouts completed, error rates return to normal levels.
What our checks recorded
We have no checks recorded from Bland AI's start time to its resolution.
Updates are Bland AI's own words from its status page (status: resolved); we never add an inferred cause. The vendor's incident page ↗